MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.570 INCHES MINIMUM AND 0.600 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 54.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -35.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 100.5 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 124.5 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 160.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 315.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 82.5 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0/+5.0 ALL RESISTANCE-TEMPERATURE POINTS |
AGAV | END ITEM IDENTIFICATION | MISCFCFOSS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | III ZERO POWER RESISTANCE | 150.000 OHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0/+5.0 |
STYL | STYLE DESIGNATOR | ROD |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AEHX | MAXIMUM POWER DISSIPATION RATING | 0.25 MILLIWATTS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 153.3 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 234.8 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
CBME | III CUBIC MEASURE | 0.022 CUBIC INCHES |