MRC | Criteria | Characteristic |
---|
AAQL | BODY STYLE | W/MTG HOLE(S)/SLOT(S), TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.750 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 5.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.500 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 2.650 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.500 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.190 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.500 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ONE TERMINAL COMMON TO EACH SECTION |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.000 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED MOUNTING HOLES |
BWGP | SECTION QUANTITY | 2 |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.430 MICROFARADS 1ST SECTION |
CQBQ | CAPACITANCE VALUE PER SECTION | 1.060 MICROFARADS 2ND SECTION |
CQJJ | NONDERATED OPERATING TEMP | 0.0 DEG CELSIUS MINIMUM AND 65.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1200.0 DC 1ST SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1200.0 DC 2ND SECTION |
CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | +0.0 TO 300.0 1ST SECTION |
CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | +0.0 TO 300.0 2ND SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 MICROFARADS 1ST SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 MICROFARADS 2ND SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 7000.0 MEGOHM-MICROFARADS |
CWQF | QUALITY FACTOR AT REFERENCE TEMP | 200.0000 |
CWSG | III TERMINAL SURFACE TREATMENT | SILVER |
PMLC | III PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 3 THREADED STUD |