Send Instant RFQ

NSN 5925-01-226-5942 (5925012265942) Circuit Breaker Parts List

Alternative NSN: 5925-01-226-5942
Item Name:Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 012265942
NCB Code: USA (01)
Manufacturers: Eaton Corp , Harris Technical Services Corp , Management Services Group Inc

ASAP Aerospace, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Customers can easily search our database to find NSN parts like Circuit Breaker AM4-Z88-1, AM4S-Z88-1, SCD51990322-001, SCD51990322-001 of Eaton Corp, Management Services Group Inc, Harris Technical Services Corp with NSN 5925-01-226-5942.

NSN 5925-01-226-5942, National Stock Number, is a 13-digit serial number assigned by the US DLA to an item that is bought, stored, and sold via the federal supply chain. Unlike part numbers, NSNs are not arbitrary and follow a specific classification system.


Part Number List for NSN 5925012265942

Characteristics Data of NSN 5925012265942

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
ADATBODY WIDTH2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
AKPXPOLE QUANTITY4
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE70.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE70.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE70.0 AMPERES AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC SECOND LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC THIRD LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS28.0 DC FOURTH LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 DC FOURTH LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT FIRST LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SECOND LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT THIRD LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERVOLTAGE FOURTH LOCATION
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS FOURTH LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY FIRST LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SECOND LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY THIRD LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 FIRST LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SECOND LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 THIRD LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY4 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, AND FOUR LINKED
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP FOURTH LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIRST LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.175 MINIMUM AT 200 PCT FIRST LOCATION AND 2.000 MAXIMUM AT 200 PCT FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.175 MINIMUM AT 200 PCT SECOND LOCATION AND 2.000 MAXIMUM AT 200 PCT SECOND LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.175 MINIMUM AT 200 PCT THIRD LOCATION AND 2.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
CRTKSWITCH TERMINAL TYPEQUICK DISCONNECT, MALE
CSSXSWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 2.5 DC
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 50.0 DC
FEATSPECIAL FEATURESPOLE FOUR TRIPS WITH VOLTS ONLY
FREQFREQUENCY IN HERTZ400.0 FIRST LOCATION
FREQFREQUENCY IN HERTZ400.0 SECOND LOCATION
FREQFREQUENCY IN HERTZ400.0 THIRD LOCATION
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY10 THREADED STUD
Thank You for Visiting ASAP Aerospace!

Before You Go, You Should Check Out Our NSN Parts Catalog! You Can Get A Competitive Quote Within Just 15 Minutes of Submitting Your RFQ.

Request for Quote