Alternative NSN: 5930-00-577-8579 |
Item Name:Switch Pressure |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 005778579 |
NCB Code: USA (00) |
Manufacturers: Detroit Switch Inc , General Electric Company |
ASAP Aerospace, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Customers can easily search our database to find NSN parts like Switch Pressure 168A2434BHP7B, 222-10NB12-222-1255, 2221255, TS1582REVAPC19 of General Electric Company, Detroit Switch Inc with NSN 5930-00-577-8579.
NSN 5930-00-577-8579, National Stock Number, is a 13-digit serial number assigned by the US DLA to an item that is bought, stored, and sold via the federal supply chain. Unlike part numbers, NSNs are not arbitrary and follow a specific classification system.
Part No | Item Name | Manufacturer | QTY | RFQ |
---|---|---|---|---|
168A2434BHP7B | Switch Pressure | General Electric Company | Avl | RFQ |
222-10NB12-222-1255 | Switch Pressure | Detroit Switch Inc | Avl | RFQ |
2221255 | Switch Pressure | Detroit Switch Inc | Avl | RFQ |
TS1582REVAPC19 | Switch Pressure | Detroit Switch Inc | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.688 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.688 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.203 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | BRACKET |
CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +60.00/+900.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL THIRD VOLTAGE |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |