MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.188 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.438 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | 4920-00-450-0553,TEST STAND,HYDRAULI |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJB | PROOF PRESSURE | 1000.00 POUNDS PER SQUARE INCH |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL THREADED HOLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +29.00/+500.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +25.00/+472.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SERRATED NUT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
THSD | THREAD SERIES DESIGNATOR | UNC ALL THREADED HOLE |