MRC | Criteria | Characteristic |
---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD 15.0 AMPERES AC AND 12.0 AMPERES DC INDUCTIVE LOAD 5.0 AMPERES AC AND 5.0 AMPERES DC LAMP LOAD 10.0 AMPERES AC AND 10.0 AMPERES DC MOTOR LOAD |
ABKW | OVERALL HEIGHT | 1.015 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 11 WIRE HOOK ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | III PURPOSE FOR WHICH DESIGNED | GENERAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOTTED HOLE SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
AKDX | WINDING QUANTITY | 1 |
AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
ADTV | III CASE MATERIAL | METAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |