MRC | Criteria | Characteristic |
---|
CQBD | BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
CQQN | (NON-CORE DATA) EXTERNAL PROTECTION TYPE AND LOCATION | OVERALL CHAFE GUARD, HEAT SHRINKABLE POLOLEFIN TUBING |
CRLL | (NON-CORE DATA) SECOND END FITTING/COMPONENT AND SURFACE TREATMENT | COMPLETE FITTING PASSIVATED |
ADJM | (NON-CORE DATA) INNER CONVEYING TUBE MATERIAL | PLASTIC, POLYTETRAFLUOROETHYLENE |
CQGH | (NON-CORE DATA) FIRST END FITTING/COMPONENT AND MATERIAL | COMPLETE FITTING STEEL, CORROSION RESISTING |
AAJD | THREAD CLASS | 3B 1ST END 3B 2ND END |
CQGM | MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
ABJH | TEMP RATING | -65.0 DEG FAHRENHEIT AND 400.0 DEG FAHRENHEIT SINGLE RESPONSE |
CQBB | (NON-CORE DATA) SECOND END RELATIONSHIP WITH FIRST END | NOT IDENTICAL |
CQJX | NOMINAL THREAD SIZE | 1.062 INCHES 1ST END 1.062 INCHES 2ND END |
ZZZK | SPECIFICATION/STANDARD DATA | 81343-AS154 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
CQRB | SEAT ANGLE | 37.0 DEGREES 1ST END 37.0 DEGREES 2ND END |
THSD | THREAD SERIES DESIGNATOR | UNJ 1ST END UNJ 2ND END |
CRWL | INSIDE SURFACE CONDITION | SMOOTH |
CBBL | FEATURES PROVIDED | ELECTROSTATIC DISCHARGE CAPABILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND 1ST END RIGHT-HAND 2ND END |
CRFY | FLOW ANGLE | 45.0 DEGREES 2ND END |
AAJP | (NON-CORE DATA) OUTSIDE SURFACE TREATMENT | PASSIVATED |
CQBG | (NON-CORE DATA) FIRST END SWIVEL ACTION CAPABILITY | NOT INCLUDED |
CQHW | (NON-CORE DATA) FIRST END FITTING/COMPONENT AND SURFACE TREATMENT | COMPLETE FITTING PASSIVATED |
CRBL | (NON-CORE DATA) SECOND END FITTING/COMPONENT AND MATERIAL | COMPLETE FITTING STEEL, CORROSION RESISTING |
AKUU | END CONNECTION DESIGN | STRAIGHT 1ST END ELBOW 2ND END |
ABKV | OUTSIDE DIAMETER | 0.950 INCHES MINIMUM AND 0.990 INCHES MAXIMUM |
ADLF | (NON-CORE DATA) HOSE OR TUBING SPEC/STD DATA | SAE AS1339,SIZE 12-81343 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
AHNC | CONNECTION STYLE | SWIVEL NUT FLARE 1ST END SWIVEL NUT FLARE 2ND END |
CRXX | MEASURING METHOD AND LENGTH | 33.000 INCHES NOMINAL WORKING |
CQCS | LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
AARX | INSIDE DIAMETER | 0.602 INCHES MINIMUM |
CMLP | THREAD QUANTITY PER INCH | 12 1ST END 12 2ND END |
ACKH | MINIMUM INSIDE BENDING RADIUS | 4.000 INCHES |
CRDW | HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
AWLS | CONNECTION TYPE | THREADED INTERNAL TUBE 1ST END THREADED INTERNAL TUBE 2ND END |
CRZY | (NON-CORE DATA) SECOND END SWIVEL ACTION CAPABILITY | NOT INCLUDED |
CRJM | OUTER COVERING ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |