Thank you for taking an interest in Spx Flow Technology Systems Inc part number 10-24504-04, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number 10-24504-04, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number 10-24504-04 Details:
Part number 10-24504-04 traces back to Spx Flow Technology Systems Inc (CAGE Code S4759), having been classified under NSN 4320013935921 and item name Pump Unit Centrifug. With its NSN, this part number belongs to FSG 43 Pumps and Compressors and FSC 4320 Power And Hand Pumps. Additional listing data derived from the NSN includes the NIIN 013935921, the INC 17988, and NCB code 01 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
FEAT | Special Features | CONTINUOUS OPERATION MOTOR IN TEMPERATURE RANGE OF M40.0 DEG F TO 212.0 DEG F; MOTOR BRACKET CAN BE TURNED THROUGH A FULL 360.0 DEG TO FACILITATE INSTALLATION; 19.0 MM OR 3/4 IN. HOSE SIZE CONNECTIONS |
AHYX | Total Head | 3.300 FEET |
ELEC | Voltage In Volts | 24 |
SUPP | Supplementary Features | HAS 2 LEAD WIRES 260.0 MM LONG |
AAYU | Intake Connection Type | UNTHREADED EXTERNAL |
AHYW | Discharge Pressure | 10.0 KILOGRAMS PER SQUARE CENTIMETER GAGE |
AJAF | Unpackaged Unit Length | 6.693 INCHES NOMINAL |
ACDC | Current Type | DC |
AHYV | Maximum Discharge Flow Rate | 7.1 GALLONS PER MINUTE |
MRC | Decoded Requirement | Clear Text Reply |
AHZE | Centrifugal Pump Design | MIXED FLOW |
AAXS | Prime Mover Cooling Medium | AIR |
AHZS | Operation Relationship Design | SIMULTANEOUS |
AHZF | Centrifugal Pump Impeller Quantity | 1 |
AHZG | Centrifugal Pump Impeller Suction Type | SINGLE |
AJAG | Unpackaged Unit Width | 2.6970 INCHES NOMINAL |
AKNA | Inclosure Type | FULLY INCLOSED |
AJAH | Unpackaged Unit Height | 2.953 INCHES NOMINAL |
AJAL | Pump Basic Material | PLASTIC |
AAXH | Prime Mover Quantity | 1 |
CSYL | Prime Mover Power Rating | 0.001 HORSEPOWER |
AENC | Pump Quantity | 1 |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAYV | Discharge Connection Quantity | 1 |
ACKL | Media For Which Designed | WATER, FRESH OR WATER, SALT |
AAYW | Discharge Connection Type | UNTHREADED EXTERNAL |
AAYD | Stage Quantity | 1 |
AAYT | Intake Connection Quantity | 1 |
AENK | Cooling Method | AIR TO AIR COOLED |
AMPS | Current Rating In Amps | 0.9 |