MRC | Criteria | Characteristic |
---|
FEAT | SPECIAL FEATURES | METRIC BUSHING MOUNT 12 MM |
AGAV | III END ITEM IDENTIFICATION | F-15I LANTRIN |
AKPX | POLE QUANTITY | 1 |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 UNTHREADED HOLE |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 1.0 AC |
CTTC | THREAD TOLERANCE CLASS | EXTERNAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES AC SINGLE LOCATION |
CRTK | SWITCH TERMINAL TYPE | KNIFE BLADE |
ABHP | OVERALL LENGTH | 1.968 INCHES NOMINAL |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
ABMK | OVERALL WIDTH | 0.074 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1.5 SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 SINGLE LOCATION |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
CPRQ | RESET METHOD | MANUAL |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
AAQL | BODY STYLE | SINGLE POLE TYPE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.492 MILLIMETERS NOMINAL |
AJEC | BOSS HEIGHT | 0.059 INCHES NOMINAL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP W/AUXILIARY LOAD TERMINAL SINGLE LOCATION |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM |
TTQY | TERMINAL TYPE AND QUANTITY | KNIFE BLADE |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.606 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.000 INCHES NOMINAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.656 INCHES NOMINAL |