MRC | Criteria | Characteristic |
---|
AAQL | Body Style | SINGLE POLE TYPE |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 0.000 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 4.0 AMPERES AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 2 SCREW |
CPRQ | Reset Method | MANUAL |
CXCY | Part Name Assigned By Controlling Agency | MAGNETIC CIRCUIT BREAKER, BX STYLE, ONE HANDLE PER UNIT, ROCKER, ACCIDENTAL-OFF PROTECTION, 1 POLE, SERIES, 50/60 HZ MOTOR START |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 SINGLE LOCATION |
FEAT | Special Features | BX STYLE HAS FLAT ROCKER ACTUATOR WITH ACCIDENTAL ACTUATION PROTECTION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AJEC | Boss Height | 0.439 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.859 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.490 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.490 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |