MRC | Criteria | Characteristic |
---|
ABHP | III OVERALL LENGTH | 5.938 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.938 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.094 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 6.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 1.125 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AWTN | OPERATING TEMP RATING | -10.0 DEG FAHRENHEIT MINIMUM AND 122.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | -10.00/+60.00 ACTUATION POINT DEGREES FAHRENHEIT AND -10.00 TO 60.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | RECTANGULAR |