MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2A SINGLE PRESSURE CONNECTION |
ABKW | OVERALL HEIGHT | 4.125 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.750 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.204 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.750 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJX | NOMINAL THREAD SIZE | 0.125 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.25/+4.00 ACTUATION POINT INCHES OF WATER |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
CTYX | CONTACT STIMULUS RATING | 5.00 DEACTUATION POINT NOMINAL INCHES OF WATER AND 0.10 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |