MRC | Criteria | Characteristic |
---|
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT HEX NUT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 110.0 AC AT SEA LEVEL SINGLE VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
FEAT | SPECIAL FEATURES | SWITCH ACTUATES IDEPEDENTLY ON THE DECREASE PRESSURE OF 1.9 INCHES OF WATER AND ON INCREASEING PREASURE OF 2.5 INCHES OF WATER |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
STYL | III STYLE DESIGNATOR | CYLINDRICAL W/BRACKET |
AARX | INSIDE DIAMETER | 0.125 INCHES NOMINAL SINGLE CONNECTION |
ABHP | OVERALL LENGTH | 4.210 INCHES NOMINAL |
ABPM | BODY DIAMETER | 7.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.276 INCHES MINIMUM AND 0.296 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 8.250 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AWTN | OPERATING TEMP RATING | 0.0 DEG FAHRENHEIT MINIMUM AND 110.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
ABKW | OVERALL HEIGHT | 8.940 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |