MRC | Criteria | Characteristic |
---|
TTQY | Terminal Type And Quantity | 2 TERMINAL BLOCK W/SCREWS |
ABHP | Overall Length | 164.0 MILLIMETERS MAXIMUM |
CWJS | Winding Operating Voltage | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 14.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 14.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 33.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 33.70 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AXGY | Mounting Method | SLOT SINGLE GROUP |
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
MRC | Decoded Requirement | Clear Text Reply |
BPLC | Winding Function And Quantity | 3 PRIMARY SINGLE COMPONENT AND 12 SECONDARY SINGLE COMPONENT |
CRBZ | Winding Operating Current | 2.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 2.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABTD | Mounting Slot Width | 7.0 MILLIMETERS NOMINAL SINGLE GROUP |
ACZC | Input-Output Phase Relationship | THREE PHASE TO TWELVE PHASE SINGLE COMPONENT |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
ABKW | Overall Height | 155.0 MILLIMETERS NOMINAL |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZX | Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
CRMJ | Winding Power Rating | 435.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
ABMK | Overall Width | 100.0 MILLIMETERS MAXIMUM |
AKNA | Inclosure Type | FULLY INCLOSED |
FEAT | Special Features | PRIMARY INTERNAL CONNECTION SPLIT TO PROVIDE DUAL CONNECTION |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 85.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |