MRC | Criteria | Characteristic |
---|
AAGR | UNABLE TO DECODE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AGAV | END ITEM IDENTIFICATION | AN/TPS-43 RADAR SET |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 3.002 INCHES MINIMUM FIRST FLANGE AND 3.005 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 1.502 INCHES MINIMUM FIRST FLANGE AND 1.505 INCHES MAXIMUM FIRST FLANGE |
AHTC | FLANGE OUTSIDE DIAMETER | 5.298 INCHES MINIMUM FIRST FLANGE AND 5.328 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.735 INCHES MINIMUM FIRST FLANGE AND 0.765 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.257 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.260 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 2.994 INCHES MINIMUM AND 3.006 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 2.834 INCHES MINIMUM AND 2.846 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 1.334 INCHES MINIMUM AND 1.346 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 1.494 INCHES MINIMUM AND 1.506 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CTFD | WAVEGUIDE LENGTH | 7.980 INCHES MINIMUM AND 8.020 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | FLANGE FACES AND INTERNAL WAVEGUIDE SURFACES MASKED FROM PAINT |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | CHROMATE ZINC ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
STYL | III STYLE DESIGNATOR | STRAIGHT TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |