MRC | Criteria | Characteristic |
---|
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 20.0 MILLIVOLTS PEAK 1ST POWER OUTPUT 40.0 MILLIVOLTS PEAK 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT 1 2ND POWER OUTPUT |
ABKW | OVERALL HEIGHT | 110.0 MILLIMETERS NOMINAL |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE 1ST POWER OUTPUT CONNECTOR, RECEPTACLE 2ND POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 2.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT 6.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES NOMINAL 1ST POWER OUTPUT 1.5 DC AMPERES MINIMUM AND 6.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
ABMK | OVERALL WIDTH | 128.0 MILLIMETERS NOMINAL |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
BGQR | OUTPUT WATTAGE RATING | 60.0 WATTS NOMINAL 1ST POWER OUTPUT 60.0 WATTS NOMINAL 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 70.0 DEG CELSIUS |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT 47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 190.5 MILLIMETERS NOMINAL |
APNX | INPUT VOLTAGE RATING | 110.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT 220.0 AC VOLTS MINIMUM AND 240.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | ALTERNATE OPERATING |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT 12.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |