Thank you for taking an interest in Coutant Lambda Ltd part number LOS-Y-24-1, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number LOS-Y-24-1, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number LOS-Y-24-1 Details:
Part number LOS-Y-24-1 traces back to Coutant Lambda Ltd (CAGE Code K5137), having been classified under NSN 6130010990643 and item name Power Supply. With its NSN, this part number belongs to FSG 61 Electric Wire and Power and Distribution Equipment and FSC 6130 Converters Electrical Non Rotating. Additional listing data derived from the NSN includes the NIIN 010990643, the INC 00740, and NCB code 01 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-099-0643 Item PartTypeName: POWER SUPPLY | 6130 | 010990643 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LOS-Y-24 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.625 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.875 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 210.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 22.8 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 25.2 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 60.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 1.6 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT AND 2.2 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | FULL RECTIFICATION |