MRC | Criteria | Characteristic |
---|
AAPN | SECTION QUANTITY | 7 |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
ABPM | BODY DIAMETER | 1.625 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.875 INCHES NOMINAL |
ADAP | MOUNTING BUSHING LENGTH | 0.375 INCHES NOMINAL |
ADAQ | BODY LENGTH | 3.934 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
AEFP | NONTURN DEVICE RADIUS | 0.531 INCHES NOMINAL |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
CBBL | FEATURES PROVIDED | GROUNDED CONTACT ARM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 100.000 PERCENT, RATED AMPERES C AND BETTER SELECT |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 75.000 PERCENT, RATED AMPERES C AND BETTER V.G. STEPPING |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 300.0 NOMINAL |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.50/+0.50 ALL SECTIONS |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 105.0 ALL SECTIONS |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -20.0/+20.0 ALL SECTIONS |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR ALL SECTIONS |
CRGM | FUNCTION CONFORMITY PER SECTION | ALL SECTIONS INDEPENDENT LINEARITY |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -2.0/+2.0 OHMS ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -1.0/+1.0 ALL SECTIONS |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 150000.0 1ST SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 2500.0 7TH SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 25000.0 5TH SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 37500.0 4TH SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 ALL SECTIONS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 275.0 NOMINAL |
AEFL | MAXIMUM RUNNING TORQUE | 1.25 INCH-OUNCES |
AEFN | NONTURN DEVICE LOCATION | AT 3 OCLOCK AND AT 9 OCLOCK |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
AXGY | MOUNTING METHOD | STANDARD BUSHING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 225.000 PERCENT, RATED AMPERES C AND BETTER INDUSTRIAL CLEARS |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 30.000 PERCENT, RATED AMPERES C FINISH |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 300.000 PERCENT, RATED AMPERES C AND BETTER FINISH |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.000 PERCENT, RATED AMPERES C FLOORING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.000 PERCENT, RATED AMPERES C DROP SIDING |
CRJS | FIXED TAP QUANTITY PER SECTION | 1 ALL SECTIONS |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 112500.0 2ND SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 15000.0 6TH SECTION |
CSBW | TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 50000.0 3RD SECTION |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS LINEAR |
TTQY | TERMINAL TYPE AND QUANTITY | 28 TAB, SOLDER LUG |