Thank you for taking an interest in Sensata Technologies Inc part number 7MC3-5-12, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number 7MC3-5-12, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number 7MC3-5-12 Details:
Part number 7MC3-5-12 traces back to Sensata Technologies Inc (CAGE Code 82647), having been classified under NSN 5925004518682 and item name Circuit Breaker. With its NSN, this part number belongs to FSG 59 Electrical and Electronic Equipment Components and FSC 5925 Circuit Breakers. Additional listing data derived from the NSN includes the NIIN 004518682, the INC 00136, and NCB code 00 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-451-8682 Item Description: Circuit Breaker | 5925 | 004518682 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7MC3-5-12 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | VIBRATIONPROOF |
AAQL | Body Style | SINGLE POLE TYPE |
AKPX | Pole Quantity | 1 |
PKWT | Unpackaged Unit Weight | 0.125 POUNDS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 32.0 DC SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.669 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
ADAT | Body Width | 0.656 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
CSSX | Switch Current Rating And Type In Amps | 7.0 DC |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
CPRX | Actuator Position Designation | AT POLE ONE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADTV | Case Material | PLASTIC |
CSWP | Switch Voltage Rating And Type In Volts | 28.0 DC |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
THSD | Thread Series Designator | UNS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
ADAQ | Body Length | 1.781 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.469 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.341 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 SCREW |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 12.0 AMPERES DC SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CPRW | Actuator Function | TRIP-RESET |
CQXF | Inclosure Protection Type For Which Designed | SHOCKPROOF AND |
Million
Parts Sold
Million
Parts Available
Thousand
Happy Customers