Thank you for taking an interest in Supertex Inc part number VP1204N2, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number VP1204N2, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number VP1204N2 Details:
Part number VP1204N2 traces back to Supertex Inc (CAGE Code 59640), having been classified under NSN 5961011943721 and item name Transistor. With its NSN, this part number belongs to FSG 59 Electrical and Electronic Equipment Components and FSC 5961 Semiconductor Devices and Associated Hardware. Additional listing data derived from the NSN includes the NIIN 011943721, the INC 20588, and NCB code 01 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5961-01-194-3721 Item PartTypeName: TRANSISTOR | 5961 | 011943721 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D20033A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABBH | INCLOSURE MATERIAL | METAL |
ABHP | OVERALL LENGTH | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM |
ADAV | OVERALL DIAMETER | 0.350 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
ALAS | INTERNAL CONFIGURATION | FIELD EFFECT |
ALBA | ELECTRODE INTERNALLY-ELECTRICALLY CONNECTED TO CASE | DRAIN |
AXGY | MOUNTING METHOD | TERMINAL |
CTMZ | SEMICONDUCTOR MATERIAL | SILICON |
CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | -40.0 MAXIMUM DRAIN TO GATE VOLTAGE AND-40.0 MAXIMUM DRAIN TO SOURCE VOLTAGE AND-6.0 MAXIMUM GATE TO SOURCE VOLTAGE |
CTQX | CURRENT RATING PER CHARACTERISTIC | 6.00 AMPERES MAXIMUM DRAIN CURRENT AND 12.00 AMPERES MAXIMUM OFF-STATE CURRENT,PEAK |
CTRD | POWER RATING PER CHARACTERISTIC | 6.0 WATTS MAXIMUM TOTAL DEVICE DISSIPATION |
CTSG | MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 150.0 DEG CELSIUS AMBIENT AIR |
TEST | TEST DATA DOCUMENT | 86360-D20033A DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |