Thank you for taking an interest in Transformer Technicians Inc part number TTI-14-250, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number TTI-14-250, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number TTI-14-250 Details:
Part number TTI-14-250 traces back to Transformer Technicians Inc (CAGE Code 96253), having been classified under NSN 5950013469706 and item name Transformer Power. With its NSN, this part number belongs to FSG 59 Electrical and Electronic Equipment Components and FSC 5950 Coils and Transformers. Additional listing data derived from the NSN includes the NIIN 013469706, the INC 32496, and NCB code 01 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-346-9706 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013469706 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TTI-14-250 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
BFMF | COOLING METHOD | SELF-COOLED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
ABHP | OVERALL LENGTH | 3.440 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.062 INCHES MINIMUM AND 2.680 INCHES MAXIMUM |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-WYE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 18.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.550 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM SINGLE GROUP AND 0.158 INCHES MAXIMUM SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRMJ | WINDING POWER RATING | 11.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 99167-5907286 DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 13 WIRE LEAD |
Million
Parts Sold
Million
Parts Available
Thousand
Happy Customers