Thank you for taking an interest in Joint Electronics Type Designation System part number PP7121 U, which is currently available for purchase today here on ASAP Aerospace. You have reached our Request for Quote (RFQ) page for this part number PP7121 U, where we make it easy to secure competitive pricing and procurement options from our staff.
Part Number PP7121 U Details:
Part number PP7121 U traces back to Joint Electronics Type Designation System (CAGE Code 80058), having been classified under NSN 6130010501009 and item name Power Supply. With its NSN, this part number belongs to FSG 61 Electric Wire and Power and Distribution Equipment and FSC 6130 Converters Electrical Non Rotating. Additional listing data derived from the NSN includes the NIIN 010501009, the INC 00740, and NCB code 01 (USA).
Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-050-1009 Item PartTypeName: POWER SUPPLY | 6130 | 010501009 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PP7121/U | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.600 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.900 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.900 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT |
AGAV | END ITEM IDENTIFICATION | AF SAT COM AIR/GRD MODEM/SYNCHRONIZER POWER SUPPLY TEST SET AN/USM-44 NSN 6625-01-042-8139 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 70000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 24.0 DC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 30.0 DC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | -65.0 TO 160.0 DEG FAHRENHEIT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 0.25 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.6 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC AMPERES MINIMUM 4TH POWER OUTPUT AND-0.2 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
CWKM | WARM UP TIME IN MINUTES | 3 |